Installation Instructions Visit the Premier Mounts website at http://www.mounts.com Page 9
PP-FCTA
PP-FCTA
Ceiling Attachment
Solid Surface
Wood Stud
Determine a suitable structure capable of supporting
the intended weight to drill the mounting holes.
Set the holes so that wires from the main ceiling
plate will angle 15 degrees outward (see Fig. 1).
®
Use a 1/8˝ drill bit to drill the mounting holes.
®
Secure the four (4) ¼˝ eye lag screws to the wood
stud in the ceiling.
°
Loop a wire through an eye lag screw (see Figure 2).
±
Twist the wire at least ve (5) times around itself to
secure it.
²
Run the other end of the wire through the turnbuckle.
³
Twist the wire at least ve (5) times around itself to
secure it.
´
Repeat steps 4-7 for the remaining three mounting
points.
The nal loop on the wire has to be tightly bent
and secured to prevent it from untwisting. Twist
the turnbuckles to ne-tune adjust.
Recheck all hardware and installation for proper
tightness and security.
Determine a suitable structure capable of supporting
the intended weight to drill the mounting holes.
Set the holes so that wires from the main ceiling
plate will angle 15 degrees outward (see Fig. 1).
®
Use a ¼˝ concrete drill bit to drill the mounting holes.
¯
Place the concrete anchors into the drilled hole and
gently tap into place using a rubber mallet or hammer.
°
Loop a wire through a concrete anchor bolt (see
Figure 2).
±
Twist the wire at least ve (5) times around itself to
secure it.
²
Run the other end of the wire through the turnbuckle.
³
Twist the wire at least ve (5) times around itself to
secure it.
´
Repeat steps 4-7 for the remaining three mounting
points.
The nal loop on the wire has to be tightly bent
and secured to prevent it from untwisting. Twist
the turnbuckles to ne-tune adjust.
Recheck all hardware and installation for proper
tightness and security.
Wood Stud Ceiling
Concrete Ceiling
Eye Lag Screw
Concrete Anchor
Proceed to the ″Securing the 1 ½˝ NPT to the
PP-FCTA″ on page 11.
Proceed to the ″Securing the 1 ½˝ NPT to the
PP-FCTA″ on page 11.
Hook the four (4) turnbuckles into the four corners of the main
ceiling plate. Then choose one of the three ceiling attachment
15°
Figure 1
Figure 2
15°
Figure 1
Figure 2